Manufactured heat pump models
Model tables, entering water conditions, efficiency values and cabinet descriptions.
Open specification ↗The original Dennis Campbell specification is available here with our extraction and source notes.
Model tables, entering water conditions, efficiency values and cabinet descriptions.
Open specification ↗Serviceability, cabinet construction and system sizing in Dennis Campbell's earlier document. Its model tables differ from the latest 16-page specification above; use that specification for product data.
Read source text ↗13 individual manufacturer photographs. Exact model numbers are withheld where the image does not establish them.













One source-linked register of all documented and open model rows, cabinet alternatives and image gaps. Source values are not independently certified performance.
Download model matrix (CSV) · Structured catalog (JSON) · Render manifest and missing references
45 extracted rows require identifier, cabinet or table clarification before they can appear as verified product pages. The original wording is preserved below.
The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 × 36 × 64 inch dimensions and flag the source discrepancy here.
The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values.
Heading says PBRC; cabinet heading says PBCD-72; rows are labelled PBSC and cannot be safely normalized.
Section title says PHHO while first four rows use PBHO.
PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier.
Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT.
Source reuses PBWW identifiers and lists four possible cabinet styles without mapping any model to a cabinet.
Four cabinet styles are mentioned but no model-to-cabinet mapping is provided.
PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated.
Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table.
| Printed identifier | Source family | Unresolved question | Evidence |
|---|---|---|---|
| PBHO-96DS12K20 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PBHO-78DS12K20 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PBHO-68DS12K20 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PBHO-64DS12K20 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-56DS12K15 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-55DS12K15 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-48DS12K15 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-46DS12K15 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-40DS12K10 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PHHO-34S12K10 | PBHO/PHHO | Section title says PHHO while first four rows use PBHO. | [DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions] |
| PBHC-34S12K10 | PBHC | PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier. | [DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions] |
| PBHC-26DK5 | PBHC | PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier. | [DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions] |
| PBHC-24DK5 | PBHC | PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier. | [DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions] |
| PBHC-20DK5 | PBHC | PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier. | [DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions] |
| PBHC-14DK5 | PBHC | PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier. | [DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions] |
| PBHT-96DS12K20 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-78DS12K20 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-68DS12K20 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-56DS12K15 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-55DS12K15 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-48DS12K15 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PBHT-46DS12K15 | PBHT | Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT. | [DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions] |
| PWWT-83DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-70DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-60DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-57DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-51DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-50DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-42DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PWWT-40DS12 | PWWT | Four cabinet styles are mentioned but no model-to-cabinet mapping is provided. | [DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions] |
| PBDH-83DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-70DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-60DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-57DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-51DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-50DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-42DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBDH-40DS12 | PBDH | PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated. | [DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions] |
| PBSM-96DS12K20 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBSM-78DS12K20 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBSM-68DS12K20 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBSM-64DS12K20 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBVE-56DS12K15 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBVE-55DS12K15 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
| PBVE-48DS12K15 | PASD | Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table. | [DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions] |
The photographs are original manufacturer equipment images. Exact model plates are not readable, so photos represent equipment types rather than specific catalog model numbers. Detailed image provenance is retained in the private project files.